Magnetic lock installation and troubleshooting

2025-02-20 15:17:58
0
When "access control" is required for passages that are frequently accessed, magnetic locks are the most durable, sturdy and safe electric locks! However, in order to achieve 100% effect in use, it is recommended that the magnetic lock must follow the following installation and use principles.

1. The magnetic lock must be at a 90-degree right angle to the door frame

The magnetic lock can be installed horizontally or vertically on the door frame, but whether the magnetic lock is installed horizontally or vertically on the door frame, it must be at a 90-degree right angle to the door frame. The ability and adsorption plate to exert maximum pulling force.

2. Regardless of whether the magnetic lock and the adsorption plate are installed on any door, exposed or embedded, the force between the two should be "face to face" in a straight line, and the suction capacity reaches 100%.

3. The magnetic lock needs to be installed indoors. The wires need to be hidden. If it is an "inward-opening door", the magnetic lock needs to be equipped with an LZ or z-shaped auxiliary frame. The magnetic lock is installed indoors, because it is exposed outside and there is a safety concern! When installing the wires, it is best to hide them in the door frame for safety.

4. The adsorption plate and the adsorption surface of the magnetic lock are not aligned

If the magnetic lock and the adsorption plate are not completely aligned, not only will the suction force be affected, but the magnetic spring inside the magnetic lock will also be unable to correctly detect whether the door leaf is closed and locked.

5. The adsorption plate cannot be locked. If there is a slight gap between the magnetic lock and the adsorption plate, the suction force will be greatly affected.

Therefore, when the adsorption plate is fixed to the door leaf, it is necessary to add a "rubber gasket" to allow the adsorption plate to have a fine-tuning function, and there is no gap with the contact surface of the magnetic lock!

6. Connection between the magnetic lock and the relay

The magnetic lock is "power off to open the door", so the power circuit of the magnetic lock must be connected to the N.C. contact on the card reader relay (Relay).